Purpose#

This page defines the high-level AD API design for a redundant ECU configuration. It addresses three main design concerns during Main/Sub switching:

  • Applying the same service request consistently to both Main and Sub systems
  • Handling MRM recovery requests while hiding internal differences between redundant and non-redundant configurations
  • Preventing API output collisions between Main and Sub

Design Principles#

Internal architectural differences (redundant vs. non-redundant) should not be exposed to external API users. From the API perspective, recovery from MRM state back to autonomous operation should be handled through a consistent request interface.

To achieve this, the design introduces:

  • Standardized service fan-out (generic_service_divider)
  • Unified MRM reset orchestration (mrm_reset_manager)
  • Active-ECU-based API output filtering (redundancy_adapi_switcher)

Existing vs Added Elements#

Existing Elements (from the Single-ECU Configuration)#

  • command_mode_decider
  • aggregator diagnostic latch behavior
    • Once diagnostics become diag ERROR, the state is latched
    • Even if diagnostics later return to diag OK, the latch is not cleared automatically
    • Latch release requires an explicit service call after human safety confirmation

Added Elements (for Redundant Configuration)#

  • generic_service_divider
  • mrm_reset_manager
  • redundancy_adapi_switcher

Service API Architecture Diagram#

Service API architecture

Open in draw.io for fullscreen

Service Fan-Out Design (generic_service_divider)#

In Main/Sub switching, a key requirement is to apply the same request coherently to both ECUs.

For example, the following service calls to command_mode_decider must be applied to both Main and Sub:

  • change_operation_mode
  • change_autoware_control

generic_service_divider republishes one incoming service request to multiple clients. This allows one request to be fanned out into ECU-specific calls (Main-targeted and Sub-targeted).

This is not limited to command_mode_decider. Any service that must be applied simultaneously to both ECUs can be added via plugins. For example, in a configuration where ekf_localizer is deployed on Sub ECU, a trigger_node service for initial pose setup can be added as a fan-out target.

Unified MRM Reset Design (mrm_reset_manager)#

Background#

MRM recovery involves both redundant-system resets and existing-system resets:

  • ECU switching-function reset
    • When resuming autonomous driving by returning Main ECU to Active after a Main→Sub switch
    • When initializing the internal state of the ECU switching function itself
  • aggregator diagnostic latch release
    • To avoid unintended automatic resume and require explicit operator judgment after safety confirmation

API Unification#

These internal reset paths are hidden behind a single external request: /system/mrm/reset. mrm_reset_manager receives this request and translates it into:

  • ECU switching reset request
  • Diagnostic latch release request

Note: /system/mrm/reset is currently a design proposal and is not yet supported as an AD API endpoint.

Initialization-Phase Control#

mrm_reset_manager also controls initialization-phase enable/disable behavior. Initialization is considered complete when:

  • Localization is set
  • Route is set
  • Autoware Control is on

During initialization:

  • aggregator latch behavior is turned off to avoid latching transient startup diag ERROR
  • redundancy_switcher_interface is notified via set_initializing to suppress unnecessary ECU switching

After initialization completes, set_initializing is updated to enable normal behavior.

In summary, mrm_reset_manager serves two roles:

  • API entry point for MRM-related external reset requests
  • Orchestrator for enabling/disabling reset target functions according to initialization phase

Minimum Sub-ECU API Set and Output Switching#

When switching from Main to Sub, Sub ECU provides a minimum API subset required for failure-related HMI reporting:

  • /api/system/diagnostics/status
  • /api/system/diagnostics/struct
  • /api/fail_safe/mrm_state
  • /api/system/heartbeat

Sub ECU runs default_adapi for this limited scope. (As a design option, emitting the full API set from both Main and Sub is also possible.)

To avoid simultaneous output collisions, redundancy_adapi_switcher applies output filtering:

  • If Main ECU is Active: stop API source-topic output from Sub ECU
  • If Sub ECU is Active: stop API source-topic output from Main ECU

Information Flow (Summary)#

  1. An external service request is received and fanned out by generic_service_divider to Main and Sub.
  2. When ECU switching is relevant, redundancy_switcher_interface handles switching-function integration.
  3. An MRM recovery request (/system/mrm/reset) is received by mrm_reset_manager and translated into switching reset + diagnostic latch release requests.
  4. During startup initialization, mrm_reset_manager controls latch behavior and switching-function enable state.
  5. API outputs are gated by redundancy_adapi_switcher so only the Active ECU side is exposed.

Constraints and Assumptions#

  • This page covers high-level design; detailed service definitions and implementation procedures are out of scope.
  • Node/service names may change during implementation.